The sequencers for manga filters are electronic devices that have been developed to intelligently manage and control the filter cleaning cycle. They are automatic, programmable and perform cleaning when necessary, thus allowing a great saving of compressed air. Versatile equipment that adapts to work in a wide range of sectors We have a wide range of models for 4, 8, 12 and 16 outputs. Optionally expandable models:
-
Structure and cover: reinforced plastic. Membrane: stainless steel. Switch: Inversor unipolar 15A 230VAC. Working temperatura: -15 a +60ºC. Protection: IP65. Download more info
-
Structure and cover: Aluminio RAL7001. Type: Rotary blades. Switch: Single-pole investor 2A 250VAC. Supply: 220-240VAC. Working temperature: -20 a +60ºC Protection: IP66. Download more info
-
Structure and cover: Aluminio RAL7001. Type: Rotary blades. Switch: Single-pole investor 2A 250VAC. Supply: 220-240VAC. Working temperature: -20 a +60ºC Protection: IP66. Download more info
-
Structure and cover: Aluminio RAL7001. Type: Rotary blade. Switch: Single-pole investor 2A 250VAC. Supply: 220-240VAC. Working temperature: -20 a +60ºC Protection: IP66. Download more info
-
Estructure and cover: Aluminum RAL 7001. Working temperature: -20 ºC a +100 ºC Drive angle: 10 ºC Switch: Inversor unipolar 10A. 250VAC Cable entry: Agujero roscado M16 Protección: IP65 Download more info
-
Estructure and cover: Aluminum RAL 7001. Working temperature: -20 ºC a +100 ºC. Drive angle: 10 ºC. Switch: Inversor unipolar 10A. 250VAC. Cable entry: Agujero roscado M16. Protection: IP65. Download more info
-
Estructure and cover: Aluminum RAL 7001. Working temperature: -20 ºC a +100 ºC. Drive angle: 10 ºC. Switch: Inversor unipolar 10A. 250VAC. Cable entry: Agujero roscado M16. Protection: IP65. Download more info
-
6 configurable analogical inputs , indepent for: Temperature RTD 2-3 threads (PT100, PT500, PT1000). Temperature Termopairs (tipes K,T,J,N,E,R,S,B). * Voltage (0-4,5V). Current (0-4/20mA puting external resistance 200 Ohmios). Resistence (0-8KOhmios). 6 open collector outputs for alarms. 3 inputs / pulse counters. Communication RS-485, CAN and Ethernet 10/100. Web Server incorporated for configuration and visualization. Download more info
-
- Supply voltage : 18 - 36 VDC.
- Power: 3W Maximun moisture.
- Humidity range: 2% or up to saturation of material.
- Penetration: 65-100 mm. Aprox. Depending on materials.
- Digital comunication: port RS-485 & optocoupler ports CAN.
- Analogue output: 2 X Analogue outputs 0/4-20 mA 16.
- Control imput: 1 optocoupler digital input for processes control.
- Working temperature: from 0 to 50 ºC.
-
- Supply voltage : 18 - 36 VDC.
- Power: 3W Maximun moisture.
- Humidity range: from 2% to saturation of material.
- Penetration: 65-100 mm. Aprox. Depending on materials.
- Digital comunication: port RS-485 & optocoupler ports CAN.
- Analogue output: 2 X Analogue outputs 0/4-20 mA 16.
- Control imput: 1 optocoupler digital input for processes control.
- Working temperature: from 0 to 50 ºC
-
- Supply voltage : 18 - 36 VDC.
- Power: 3W Maximun moisture.
- Humidity range: from 2% to saturation.
- Penetration: 65-100 mm. Aprox. Depending on materials.
- Digital comunication: port RS-485 & optocoupler ports CAN.
- Analogue output: 2 X Analogue outputs 0/4-20 mA 16.
- Control imput: 1 optocoupler digital input for processes control.
- Working temperature: from 0 to 50 ºC.
-
Kilowattmeter configuration using 2 keys. Display in kilowatts or in% of the nominal power. Selection of the external measurement transformer. Scaling of the measurement to the working range. Start timing. Filter of measure by number of samples. Display in% of the nominal power, increment filter of the reading per step. Programming of 2 set points (SET0, SET1) with relay output. Download more info
-
Power supply: 24VDC / 24-230VAC. Maximum nominal power required: 0,5VA 4,5VA. Relay output: Contacto conmutado 6amps@250VAC. Relay status: Powered contact in vertical position. Performance angle: 30º ±10º Working temeperature: -10º - 50º Encapsulated: Resina epoxy. Material: stainless steel exterior. Weight: 0,7kg. Download more info
-
- Keyboard taring, range and filter variation, negative weight, zeroing, and autozero.
- Configuration of 3 preselectable alarms.
- 5 red digits for display and 3 keys for configuration, adjustment, and control.
- 3 optocoupled digital outputs for alarms.
- 2 optocoupled digital inputs, counter, and reset.
- 1 load cell input, 24-bit resolution.
- Up to 8 350Ω/16 700Ω load cells.
- 16-bit 0/4-20mA analog output, configurable.
- Two-wire optocoupled half-duplex RS-485 communication.
- CAN communication optocoupled.
- Supply voltage: Universal input 90-264VAC..
- Operating temperature: from 5ºC to 40ºC.
- Mounting on 19'' rack or transpanel.
-
Galvanic isolation of 3 channels. Warning Leds of the state of transmission / reception and supply. Selection of interface RS-422/485 by means of microswitch. Length of maximum transmission: 1200m. braided pair. Maximum transmission speed: 57600 bauds. Supply: 230VAC. Assembly on rail DIN EN50022/EN50035. Download more info
-
Galvanic isolation of 3 channels. Warning Leds of the state of transmission / reception and supply. Selection of interface RS-422/485 by means of microswitch. Length of maximum transmission: 1200m. braided pair. Maximum transmission speed: 57600 bauds Supply: 230VAC. Assembly on rail DIN EN50022/EN50035.
-
Connection through RJ-45. Up to 6 connections maximum. Mounting on DIN rail EN50022 / EN50035.