• The LE4-116-DD1 is a local module for 8 digital outputs and 8 digital inputs.
    • Brand or Manufacturer: KLOCKNER / MOELLER / EATON
    • Reference: LE4-116-DD1
    PRICE TO CONSULT * Discontinued modules (Availability unless sold)
  • Supply voltage: 230VAC +10% -15% / 50/60 HZ. Power: 20 VA. Working temperature: From 0 up to 40 ºC. Sensitivity: Tuerca M18 hierro, 100mm. Degree of protection of the coil and cabinet: IP65. Minimum detection speed: 0,5 m/sg a 2,5 m/sg. Contacto Alarma1: N.C. 5 A/230VAC Libre de Potencia. Contacto Alarma2: N.C. 5 A/230VAC Libre de Potencial . Control cabinet dimensions: 200 X 250 X 150. Maximum distance from the coil to the cabinet: 100 m. Download more info
  • Supply voltage: 230VAC +10% -15% / 50/60 HZ. Power: 20 VA. Working temperature: From 0 up to 40 ºC. Sensitivity: Tuerca M18 hierro, 100mm. Degree of protection of the coil and cabinet: IP65. Minimum detection speed: 0,5 m/sg a 2,5 m/sg. Contacto Alarma1: N.C. 5 A/230VAC Libre de Potencia. Contacto Alarma2: N.C. 5 A/230VAC Libre de Potencial. Control cabinet dimensions: 200 X 250 X 150. Maximum distance from the coil to the cabinet: 100 m. Download more info
  • Supply voltage: 230VAC +10% -15% / 50/60 HZ. Power: 20 VA. Working temperature: from 0 up to 40 ºC. Sensitivy: Tuerca M18 hierro, 100mm. Degree of protection of the coil and cabinet: IP65. Minimum detection speed: 0,5 m/sg a 2,5 m/sg. Contacto Alarma1: N.C. 5 A/230VAC Libre de Potencia. Contacto Alarma2: N.C. 5 A/230VAC Libre de Potencial . Control cabinet dimensions: 200 X 250 X 150. Maximum distance from the coil to the cabinet: 100 m. Download more info
  • Supply voltage: 230VAC +10% -15% / 50/60 HZ. Power: 20 VA. Working temperature: From to 0up to 40 ºC. Sensitivity: Tuerca M18 hierro, 100mm. Degree of protection of the coil and cabinet: IP65. Minimum detection speed: 0,5 m/sg a 2,5 m/sg. Contacto Alarma1: N.C. 5 A/230VAC Libre de Potencia. Contacto Alarma2: N.C. 5 A/230VAC Libre de Potencial . Control cabinet dimensions: 200 X 250 X 150. Maximum distance from the coil to the cabinet: 100 m. Download more info
  • Supply voltage: 115-230 VAC 50/60 Hz.Power: 20VAOperating temperature: 0 to 40 ° C.Contact Alarm 1 and 2: N.C 10A / 230VAC Potential free.Minimum speed - maximum detection: 0.5 m / sg - 2.5 m / sg.Distance coil-cabinet cable: Maximum: 200 m.Wireless coil-closet distance: Maximum: 100 m in direct vision.Protection degree coil and cabinet: IP67.Communications: Ethernet / RS-485.
    Sensitivity (*) * Height from top coil base 30mm: Steel dial Ø 10mm 80mm: Steel dial Ø 20mm 150mm: Steel dial Ø 50mm

    Download more info

  • The possibility of wireless communication between the control cabinet and coil allows to save costs in the installation if either of the two elements must be placed in places of difficult access. FEATURES: - Easy installation and configuration. - Maximum range: 100m, in direct vision. - Valid for any single or double coil model. NOTE: * For proper operation this add-on must be pre-configured at the factory.
  • The sequencers for manga filters are electronic devices that have been developed to intelligently manage and control the filter cleaning cycle. They are automatic, programmable and perform cleaning when necessary, thus allowing a great saving of compressed air. Versatile equipment that adapts to work in a wide range of sectors We have a wide range of models for 4, 8, 12 and 16 outputs. Optionally expandable models:
    Salida analógica Salida RS-485 Salida analóigca + RS-485
    • Supply voltage : 18 - 36 VDC.
    • Power: 3W Maximun moisture.
    • Humidity range: 2% or up to saturation of material.
    • Penetration: 65-100 mm. Aprox. Depending on materials.
    • Digital comunication: port RS-485 & optocoupler ports CAN.
    • Analogue output: 2 X Analogue outputs 0/4-20 mA 16.
    • Control imput: 1 optocoupler digital input for processes control.
    • Working temperature: from 0 to 50 ºC.
    Download more info
    • Supply voltage : 18 - 36 VDC.
    • Power: 3W Maximun moisture.
    • Humidity range: from 2% to saturation.
    • Penetration: 65-100 mm. Aprox. Depending on materials.
    • Digital comunication: port RS-485 & optocoupler ports CAN.
    • Analogue output: 2 X Analogue outputs 0/4-20 mA 16.
    • Control imput: 1 optocoupler digital input for processes control.
    • Working temperature: from 0 to 50 ºC.
    Download more info
    • Supply voltage : 18 - 36 VDC.
    • Power: 3W Maximun moisture.
    • Humidity range: from 2% to saturation of material.
    • Penetration: 65-100 mm. Aprox. Depending on materials.
    • Digital comunication: port RS-485 & optocoupler ports CAN.
    • Analogue output: 2 X Analogue outputs 0/4-20 mA 16.
    • Control imput: 1 optocoupler digital input for processes control.
    • Working temperature: from 0 to 50 ºC
    Download more info
    • Supply voltage : 18 - 36 VDC.
    • Power: 3W Maximun moisture.
    • Humidity range:  2% or up to saturation of material.
    • Penetration: 65-100 mm. Aprox. Depending on materials.
    • Digital comunication: port RS-485 & optocoupler ports CAN.
    • Analogue output: 2 X Analogue outputs 0/4-20 mA 16.
    • Control imput: 1 optocoupler digital input for processes control.
    • Working temperature: from 0 to 50 ºC.
    Download more info
Go to Top